EATON FAZ-C6/1-NA-SP Current Limiting Supplementary Protector, 277/480 V AC, 6 A, 10 to 14 kA Interrupt, 1 Poles, Thermal Magnetic Trip
Cutler-Hammer Series FAZ-C6/1-NA-SP
EATON FAZ-C6/1-NA-SP Current Limiting Supplementary Protector, 277/480 V AC, 6 A, 10 to 14 kA Interrupt, 1 Poles, Thermal Magnetic Trip
In Stock: 3more info
|
BrandCutler-Hammer Series
MFG #FAZ-C6/1-NA-SP
Werner Part #3988515
In Stock: 3more info
|
BrandCutler-Hammer Series
MFG #FAZ-C6/1-NA-SP
Werner Part #3988515
Product Description
EATON Supplementary Protector, Current Limiting, Series: FAZ, 277/480 V AC, 6 A, 50/60 Hz Frequency, 10 to 14 kA Interrupt, Thermal Magnetic Trip, 1 Pole, Lever/Toggle Actuator, Standard Terminal Connection, 18 to 6 AWG Wire, IP20 Enclosure, DIN Rail Mounting, -40 to 75 deg C, 0.7 in L x 2.97 in W x 4.13 in H Dimensions, Nylon
Attributes
Documents
Applications
Warranty
Features
Attributes
Actuator TypeToggle Lever
Connection TypeStandard Terminal
Country of OriginES
Dimensions0.7 in L x 2.97 in W x 4.13 in H
Enclosure TypeIP20
Frequency Rating50/60 Hz
Interrupt Rating10 to 14 kA
ManufacturerEaton
MaterialNylon
Number of Poles1
SeriesFAZ
Size of Wire18 to 6 AWG
Suitable For Use WithSpectra RMSâ„¢ Series TDF, TDR, TDM, E150, SE150, SF250 and SG600 Frame Molded Case Circuit Breaker
Generation - Conventional Energy, Renewable Energy, Alternative Energy, Marine Vessels and Equipment, Datacenters, IT Space, CI and Hyper Converged, Convenience Receptacle Circuits, Motor Control Circuits, Load Circuits Leaving The Equipment, HACR Equipment, PLC I/O Points, Computers, Power Supplies, Control Instrumentation, Relays, UPS, Power Conditioners and Circuit Protection Applications
Warranty
1 year
Features
Current limiting design provides fast short-circuit interruption that reduces the let-through energy, which can damage the circuit
Thermal magnetic over current protection
Trip-free design breaker can not be defeated by holding the handle in the On position
A color coded red/green indicator provides immediate visual indication of device status (green for Off, red for On) and isolation function
Power to the circuit breakers can be fed from the line or load side
Captive screws cannot be lost
To save installation time, bus connectors and feeder terminal facilitate mounting and wiring of multiple miniature circuit breaker arrays in control panel assemblies
SWD (switching duty) suitable for switching fluorescent lighting loads
C curve devices are suitable for applications where medium levels of inrush current are expected
C curve devices provide a medium magnetic trip point